epikoinoniatopothetisiproiontaΑρχικήflag

 

THE DECALOGUE INSTALLER

erg

DOUBLE WALL

For proper installation, operation and aesthetics of the chimney follow the instructions below:

  1. By alfadonima bring the vertical line on the basis of which will align the brackets.
  2. Block with plugs INOX bases of the wall studs.
  3. Place the triangular braces every 5 steps, starting from the bottom of the vertical section of the chimney
  4. Starting the installation of the chimney from the bottom up driven by an arrow printed on the label CE.
  5. Simple props type O are placed every 2 meters below the blocking phases of two.
  6. The pieces interlock between male - female, the male external mantle up.
  7. We use each piece and the special formulation of silicone gasket three aspects for complete sealing
  8. The compounds of the pieces put collar lock (phase) to make the system more rigid the chimney.
  9. The final height of the chimney should follow the calculations the table below.
  10. In each place chimney termination for wind and antivrochiki protection system.
  11. .

SINGLE WALL

  1. By alfadonima bring the vertical line on the basis of which will align the brackets.
  2. Block with plugs INOX bases of the wall studs.
  3. Place the triangular braces every 5 steps, starting from the bottom of the vertical section of the chimney
  4. Starting the installation of the chimney from the bottom up driven by an arrow printed on the label CE.
  5. Simple props type O are placed every 2 meters below the blocking phases of two.
  6. The pieces interlock between male - female and female to the top.
  7. We use each piece and the special formulation of silicone gasket three aspects for complete sealing
  8. The compounds of the pieces put collar lock (phase) to make the system more rigid the chimney.
  9. The final height of the chimney should follow the calculations the table below.
  10. In each place chimney termination for wind and antivrochiki protection system.

selida_107

ΤECHNICAL INFORMATION

When the chimney is near the sea at a distance of up to 1 km and the outer sheath shall be of sheet INOX AISI 316L
For condensing boilers high internal sheath should be definitely out of sheets INOX AISI 316L
When the chimney goes through the roof using wooden head tilted, and the distance from the wood is 8 cm and choose the range of HI LINE PLUS
The maintenance of the chimney should be at least once a year.
The accessories and chimney to avoid contact with other metals and IM oxydomena because although stainless steel, impregnated by contact with the oxidation.

REASONS FOR SELECTING PRODUCTS DIAMANTIS S.A.

Certified by CE
Unique resistance to corrosion of the exhaust
Suitable efkolotopothetoumena accessories, parts supply and support control
Minimal maintenance
Low level of pollution contributing effectively to global warming
Attractive design - Unparalleled aesthetics
The limit of plate thickness 0,4 mm/0.5mm defined by European Regulation EN 1856 1-2 corrosion resistance of metal
Perfect operation of boiler - 40% decrease legibility

 

SPECIFICATIONS

 

CHIMNEYS DIAMANTIS S.A.

ORYKTES

REFRACTORY

CERAMIC

GROOVED SURFACE

NONE

HIGH

HIGH

LOW

HEAT TREATMENT

EXCELLENT

POOR

POOR

POOR

SEAL WATER

EXCELLENT

POOR

POOR

POOR

ΟΞΙΝΗ ΑΝΤΙΣΤΑΣΗ

EXCELLENT

EXCELLENT

EXCELLENT

EXCELLENT

ACID RESISTANCE

LOW

HIGH

HIGH

HIGH

ASSOCIATION MATERIAL

FLEXIBLE

STARK

STARK

STARK

WEIGHT

10

100

130

130

RECYCLABLE

YES

NO

NO

NO

REPLACEMENT COST COMPARED WITH INITIAL COST OF THE FACILITY

1 Χ
INITIAL COST

5 Χ
INITIAL COST

5 Χ
INITIAL COST

5 Χ
INITIAL COST

MAINTENANCE

1 EACH YEAR

ONCE A YEAR

ONCE A YEAR

ONCE A YEAR

MEAN LIFE

20 YEARS

8 YEARS

8 YEARS

8 YEARS